Roof systems · Single-ply thermoplastic

TPO / PVC restoration

Thermoplastic that still holds a seam is a restoration, not a tear-off. Clean it, seal the laps and put a fluid-applied membrane over the whole field.

  • No tear-offBuilding stays open
  • Pr305Primer required under either topcoat
The substrate

What happens to TPO and PVC

Thermoplastic membranes lose plasticizer and top-ply thickness as they age. The sheet chalks, goes brittle at the laps and starts to crack at the seams and around penetrations long before the field membrane fails.

That aging profile is what makes single-ply a good restoration candidate. The membrane is still a continuous, adhered substrate. A restoration system renews the weathering surface and the seams without touching the insulation or the deck.

A white-coated flat roof with rooftop units on a one-story retail building beside a parking lot, seen from above
A white-coated single-ply roof on a retail building, seen from above.

A coating job when

  • Seams and laps intact or repairable
  • Insulation dry on a moisture scan
  • Sheet adhered or fastened, no billowing
  • Ponding water is the main complaint

Not a coating job when

  • Wet insulation across more than a quarter of the roof
  • Shrinkage pulling flashings off walls and curbs
  • Membrane too thin to hold an adhesion pull test

Not sure? Send photos and a core cut. A rep will call it.

The system

The build-up, in order.

For roofs that pond or drain slowly. Pr305 goes down first, then Si750 over the primed sheet.

  1. Clean & prep

    Scrub with Pr325 cleaner diluted 1:4, keep it wet for 15 minutes, then power wash at 2,000 psi or more and rinse to clean water. Let it dry. Replace wet insulation flagged on the moisture scan. Pull-test a 2 × 2 ft patch before you order.

  2. Prime

    Pr305 blocks plasticizer migration on PVC and bonds aged TPO — 0.5 gal per 100 ft² on TPO, 1 gal per 100 ft² on PVC. Required under Si750 on TPO and PVC.

    Pr305 Single-Ply Primer1 gal / 200 ft²
  3. Seams & details

    Brush-grade mastic on every lap, curb, drain and penetration. Embed polyester fabric at splits and open seams.

    Si790 Silicone Mastic1 gal / 60 lin ft
  4. Walkways

    Around units and along service paths, set into wet topcoat and clipped at the corners.

    GripTite Walkway Pad Walkway ProtectionSized to layout
Cross-sectionSilicone route
  • 04 · TopcoatSi750
  • 03 · Seams & detailsSi790
  • 02 · PrimePr305
  • Substrate · Aged TPO / PVC membrane

Thickness not to scale. Optional steps appear here when switched on in the estimator below.

Material estimator

Rough quantities for this roof.

Enter the roof and get gallons and containers for the route above. It is a planning number, not a bill of materials — your rep confirms coverage before anything ships.

Chemistry
Target thickness
30 dry mils of silicone over the field
Auto from area: one lap per 10-ft sheet
Auto: one per 2,500 ft²

Estimate

25,000 ft² · 30 dry mils · silicone
  • 02Pr305 Single-Ply PrimerPrime · 1 gal / 200 ft²138 gal28 × 5-gal pails
  • 03Si790 Silicone MasticSeams & details · 2,500 lin ft · 10 penetrations49 gal25 × 2-gal pails
  • 04Si750 Silicone Roof CoatingTopcoat · 30 dry mils536 gal9 × 55-gal drums + 9 × 5-gal pails
  • 05GripTite Walkway Pad Walkway ProtectionWalkways · Rolls and clipsSized to the layout — your rep quotes it

Liquid product, all steps723 gal

Rough estimate for planning. Actual coverage depends on surface porosity, texture, application method and verified mil thickness. Confirm with the TDS and your rep before ordering.

Proof

Case studies.

Case studies are on the way.

Documents

The data sheets for this route.

Published TDS and SDS for the silicone route. Ask your rep for any sheet not listed; the spec letter comes from your rep.

Open the resource library
TDSPr305 Technical Data SheetTechnical data sheet · Rev. 08/31/2026 · 2 pages · PDF · 118 KBDownload (opens in a new tab)SDSPr305 Safety Data SheetSafety data sheet · Rev. 08/31/2026 · PDF · 154 KBDownload (opens in a new tab)TDSSi790 Technical Data SheetTechnical data sheet · Rev. 08/18/2026 · 2 pages · PDF · 88 KBDownload (opens in a new tab)SDSSi790 Safety Data SheetSafety data sheet · Rev. 05/10/2026 · PDF · 234 KBDownload (opens in a new tab)TDSSi750 Technical Data SheetTechnical data sheet · Rev. 08/18/2026 · 2 pages · PDF · 90 KBDownload (opens in a new tab)SDSSi750 Safety Data SheetSafety data sheet · Rev. 05/10/2026 · PDF · 228 KBDownload (opens in a new tab)

Order through your rep.

Reps confirm coverage and write the spec letter. Send the estimate, or call 1-812-776-6727.